Livengood Info Site Home
 
Contact Us at Livengoo
 
ROOM DESIGN
AMBULATION
DISASTER/MCI
SURGE CAPACITY
WORKFLOW
HOSPITAL PRODUCTS
E-STORE
 
           
Room Design
Expand Capability and Decrease Cost
           
 
Patient Space Before Livengood
 
 
 
Acuity-Adaptable Design - Increase Acuity-Level through Platform Configuration.
Cost Savings - Build Headwall to AIA Minimum Requirements and use the Platform for Mobile “Extras”.
Patient Outcomes - Increase Nurse-Patient Contact and Empower Patient Mobility.
Workflow - Increase Staff Efficiency through Cart Consolidation.
Patient Space - Expand Beyond the Bed throughout the Room & Hospital.
Consolidate Equipment - Decrease Room & Hallway Clutter, Improve Transport and Mobility.
Surge Capacity - A Rapid, Cost-Effective System providing ICU-Level Care Anywhere.
 
Patient Devices
8 Power Outlets
2 Oxygen Tanks
2 IV Poles
IV Pumps
Suction
Chest Tubes
Drains & Catheters
Equipment
Monitor Defibrillator
Computer
Medication Locked Drawers
Procedure Tray
Bins & Baskets
Ventilator
Battery
Carts
Medication
Supply
Computer
Procedure
Equipment
Bedside
 
Compatible with Mounting Systems from…
Compatable Products
 
Patient Space - No Longer Defined by the Bed
 
  Surge Capacity
SK-00002
  Workflow
SK-00003
  Disaster/MCI
SK-00004
  Pediatric
SK-00005
 
         
 
dim
     
Technical Specifications
   
Dimensions and Weight
Base Unit (no IV Pole, no Rings)
Width 23 ½”
Depth 24 ¼”
Height (to top surface) 34“
Weight 103 lbs
Maximum Dimensions (IV Pole & Rings)
Width 25 ½”
Depth 24 ¼”
Height (to top of IV Pole) 73 ¾”
Weight 115 lbs
Weight Capacity
Total Equipment Weight Capacity: 147.6 pounds (67 kg)
IV Pole (each)
Equipment: 30 lbs (13.6 kg) - Below marker line
Fluids: 3 liters
Top Surface: 100 pounds (45.4 kg)
Oxygen Rings(each): 15 pounds (6.8 kg)

 
   
Standards and IEC Classifications
Class I Equipment – Accessible conductive parts cannot become live in the event of a basic insulation failure because of the way in which they are connected to the protective earth conductor.
Mode of Operation - Continuous
Type B Applied Part
IPX1 - Protected against dripping water
Electrical Specifications
Input: 120V AC 60Hz - 10A
Output: 120V AC 60Hz - 10A Maximum from total of all 8 outlets
Circuit Breaker: 10A Lighted(green) Circuit Breaker - External
Retractable Cord: 10 foot, 10A, Hospital Grade(Green Dot)
Outlets: Hospital Grade(Green Dot)
Isolation Transformer: 120VAC, 50/60Hz, 10A; Input = Output.
Grounding: An Equipotentiality post is provided externally on the back of the electrical box for attachment of medical devices that may be located on the Platform.
 
   

Colors Available
Shale
color swatches
Fossil